Home>Products>Wind-electric inverter>Wind grid tied inverter

Appearance

 

Description

Combined to the grid: fan grid inverter power generation process, no human control, and automatic detection exchange network whether meet the combined to the grid conditions at the same time also can test whether the wind turbine out enough energy, when the dc voltage reach a set start point voltage, will be combined to the grid.

fan combined to the grid system consists of wind power generator, unloading device, grid inverter, power distribution measurement equipment composition. in small wind power generation system in recent years, it has been the new trend of wind machine application.


It can generate electricity will directly provide regular grid or independent from network system. This new type of
application for wind power generation more flexible, and also provides the users indirect power supply; Fan produce electric energy can directly to users, and can also will spare part directly into the power grid, and don't need is stored in the battery. Due to save the cost expensive and maintenance cost high storage battery, the wind machine parallel in the use of technology to save a huge outlay cost. When the winds reach cut wind speed, wind generator a communication power after rectification, inverter to crush after power grid, when the wind speed is too big, make fan overload operation, unloading load part access, ensure the constant power operation.

System

 

 

Parameter

Model

TLS-WO

1KS

TLS-WO

1.5KS

TLS-WO

2KS

TLS-WO

3KS

TLS-WO

4KS

TLS-WO

5KS

TLS-WO

10KS

Input

MPPT voltage range

DC 100~450V

DC 100~450V

Start voltage

DC 100V

DC100V

Rated voltage

DC 360V

DC 360V

Output

Power

1KW

1.5KW

2KW

3KW

4KW

5KW

10KW

Rated voltage

185~264 VAC

185~264 VAC

Frequency

50/60Hz

Phase

Single phase

Single phase

Power factor

0.95

THD

At rated power and the sine wave <3.5%

Max current

4.3A

6.5A

8.7A

13A

17.4A

21.7A

43.5A

Efficiency

98%Euro efficiency:96.4%

Stucture

Protection degree

IP65 / NEMA 4X

IP20 /NEMA 4X

Cooling method

Natural cool

Noice

<50dB

Data interface

External RS 232/485

Protection

Inverter

Input over voltage, output short circuit, overload overheat

Grid

Anti-islanding(IEEE 1547),over/under voltage of grid, over/under frequency of grid

Environment

Operation temperature

range

-10~4050℃

Stored temperature

-25~60

Relative humldity

0~100%

Environment

Have no corrosion gas, flammable gas, oil mist,dust etc.

Standby power 

consumption

<25.0mW

Size

W*H*Dmm

*****

Weight

KG

15

15

15

15

15

15

25

PDF Download